Infant Radiant Warmer – Neocare

Providing a warm welcome for your precious newborn

The NEOCARE® system serves its purpose in providing the optimum environment for newborns/infants. Well designed incorporate the latest medical technology, the NEOCARE® provides a balance of performance, functionality and safety – making it suitable for all environments from labor to neonatal ICUs. It has many optional features available and can be configured to meet specific care area and clinic requirements. The NEOCARE® stands out from the market as a efficient and affordable solution with its long work life and low maintenance costs.
The NEOCARE® allows visiting clinicians to stay cool and comfortable whilst helping babies staying warm, content and safe.

Product features:

1. Optimal thermal environment

  • Sophisticated electronic controller – feature high precision temperature sensors (+/- 1.0ºC), allowing for an optimal thermal environment and continuous monitoring of baby’s condition.
  • Thermal care – Special CE approved 750W ceramic heater is used to ensure fail safe heating and to provide maximum effectiveness. IR radiation is beamed from a quartz heater by a parabolic reflector.
  • Apgar timer – the Digital Apgar timer is switched on at the moment of birth of the baby and an acoustic alarm will sound after 1.5, 10, 15 and 20 minutes, reminding to examine the new born according to the Apgar scheme.
  • Baby probe – high sensitivity thermistor probe (Range: 28°C to 38°C, Accuracy: +/- 0.2°C)
  • Large mattress – ample space for equipment and clinicians during critical resuscitation procedures. Tilting mechanism for Trendelenburg and Fowler position. The acrylic sidewalls can be positioned upward or downward to helps clinicians work with ease in any clinical setting.

2. Functionality

  • X-Ray cassette tray – The Neonatal Resuscitation Unit heater box swivels away from bed to make room for an X-ray unit. Convenient tray assists you to achieve accurate X-rays without disturbing the infant.
  • Observation lamp: A halogen based observation light facilitates to focus the light on any area of the bed.
  • Ancillary equipment – storage includes two drawers and one shelve to hold equipment and other essentials. Also, numerous shelves and poles
  • Energy efficient – low voltage requirement 220-230 volts, 50Hz
  • Mobility – easy manoeuvrability and stability, with wheel locks.
  • User-friendly – temperature control and large digital display screen for easy monitoring and use.

3. Safety

  • Pre-warming mode – enables preparation of the device so it is ready for the baby at a moment’s notice. The pre-warming mode is a “silent” mode that does not have any unnecessary alarms so the clinicians can focus on the arriving baby, not the equipment.
  • Sophisticated alarm system – notifies clinicians if there is a problem with the baby’s thermal condition. Both acoustic and visual alarms assist in maintaining a stable, safe environment for the infant.
  • Automatic Heater output cut-off & power failure – after reaching on set required temperature.
  • Phototherapy lights – includes six halogen lights for Jaundice treatment in newborn babies.

4. Optional features

Extra features can be added to the NEOCARE® to upgrade its capabilities, such as:

  • Resuscitator – allows the resuscitation of the distressed newborns in delivery room or in case of emergency. Reanimation is preformed with positive pressure to the mask or endotracheal tube with manual control and free expiration. The minimum and maximum pressure values can be preset and are clearly indicated on the manometer. The Resuscitation operates when connected to the air-oxygen mixer or through any other flow meter.
  • Electrical slow suction – The slow suction unit is designed to work on latest diaphragm technology and results in being maintenance free and provides high performance. This vacuum level can be adjusted with the regulator. A vacuum gauge is provided to monitor the pressure. The suction collection jar is unbreakable and it can be easily removed and sterilised.
  • Phototherapy unit  A halogen based phototherapy unit provided for hyperbilirubinemia management. Three halogen lamps are fitted on either side of the overhead heater box. It is fitted in an angled position to focus the radiation on the Infant for maximum effectiveness.
  • Baby weighing scale  A built in digital weighing scale allows you to measure the weight without disturbing the infant.

Certification and approval

Helping reshape neonatal care. From delivery to discharge, every step of the way. 

Wewak Hospital and Kimbe Hospital were proud recipients of the NEOCARE® (Neonatal Radiant Infant Warmer 300A). Trade Link International Limited successfully installed and commissioned infant warmers onsite, also providing after-sales support, training, and availability of spare parts.

Trade Link International Limited is a certified vendor for many reputable manufacturers for a wide range of medical equipment.

For more product information or schedule a demonstration, please contact us at: sales@tlipng.com